Iesna lm 79 lm-80 software

The document covers luminous, radiant, or photon flux maintenance. Lumen maintenance testing, lm80 testing provided by led package. Secure pdf files include digital rights management drm software. The end point of the extrapolation is typically 70% of the initial light output. Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for shenzhen jufei optoelectronics co. Iesnalm80 measuring lumen maintenance of led light sources is an. Lumen maintenance launching the energy iesna lm 80 2008 iesna. Vektrex lm80 systems are optimized for lm8008 and lm8015 compliance testing for low, mid and high power leds, modules, cobs, and arrays operating in infrared, visible, or uv. Optimized using computational fluid dynamics software to ensure long led and driver lifespan. The north american lm79 and lm80 standards have been around for some time and are useful in characterising the performance of led products. Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for shineon beijing technology co. L70 is a lifetime measurement criteria developed by iesna illuminating engineering society of north america to evaluate the useful lifetime of an led luminaire in terms of the expected number of operating hours until the light output has diminished to 70% of initial. Measuring luminous flux and color maintenance of led.

Lumen maintenance launching the energy iesna lm 80. Understanding lm79 reports office of energy efficiency. This approved method describes the procedures to be followed and precautions to be observed in performing reproducible measurements of total luminous flux, electrical power, luminous intensity distribution, and chromaticity, of solidstate lighting ssl products for illumination purposes, under standard conditions. Tests according to lm79, lm80, tm21, istmt and tm30. In recent times, the term lm79 testing has become part of our lighting. Maintenance optical aging chamber is according to ies lm79, ies lm80. Aug 26, 2010 labspheres tocs system conforms to iesna lm79 and lm80 recommendations for led characterization. Ies lm7908 measurement and test report for statement. Epa energy star manufacturers guide requires l70 of 25,000 or 35,000 hours. Tests according to lm79, lm80, tm21, istmt and tm30 asselum. Lm80, lm79, tm21, istmt green creative your partner for. Observations of led light source failures including failure observations of led light source failures. While lm79 measures several aspects of a complete fixture, lm 80 solely measures the lumen depreciation of the led module.

The main purpose is that measure and records the led lumen maintenance change along with time, in other word, it is applied to test led aging life. Led lifespan based on iesna lm8008 results and calculated per iesna tm2111 methodology. Led samples for iesna lm80 testing consist of units built from a minimum of three manufacturing lots with each manufacturing lot built from different wafer lots built on nonconsecutive days. In order to read a secure pdf, you will need to install the fileopen plugin on your computer. The digital signature may be available only under the adobe software above version 7. Energy star manufacturers guide for qualifying solid state. Each sample is soldered to all of the reliability stress boards for a given set of iesna lm80 tests. Lm 79 measures a luminaire or integral lamp as a system and measures light output flux, electrical power, chromaticity. Lm79 testing captures performance characteristics of products that feature. Available in a range of integrating sphere sizes from 20 to 76 inches, the tocs systems are designed for both 2pi and 4pi measurement geometries. Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for samsung electronics co. Ies lm84 approved method for measuring luminous flux. Lighting manufacturers should be aware of the latest us department of energy doe regulations and test methods for led lamps in the united states. Method for electrical and photometric \rmeasurements of general service incandescent filament \rlamps\r10 cfr 430 subpart b.

Measuring luminous flux and color maintenance of led packages, arrays, and modules. Precision diecast aluminum, lens frame and mounting arm. The lm80 standard calls for operating a set of led devices for a minimum of 6,000 hours under well controlled operating conditions e. The north american lm79 and lm80 standards have been around for some. Lm80, lm79, tm21, istmt green creative your partner. R2dg51505010 page 5 of iesna lm8008 test report 1. Lm80 provides no determination or estimation of expected life or lumen output beyond test data. Optical and electrical measurements of solidstate lighting products, helps measure lightemitting diode led and organic lightemitting diode oled products. Lm80, lm79, l70 and tm21, what are the differences for. America iesna approved method for taking lm80 data and making useful. The standards apply to lifetime projection of led package, array or. The standard does not provide guidance for extrapolation of testing results. Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for edison opto corporation 4f,no.

It is the illuminating engineering society of north america iesna approved method for taking lm 80 data and making useful led lifetime projections. Aug 25, 2010 the tocs complies with iesna lm79 and lm80 standards, delivering accurate and reproducible led measurements. All green creative product testing are performed according to lm7908 in an. Ies standard file format for the electronic transfer of photometric data and related information. Rab led luminaires and led components have been tested by an independent laboratory in accordance with iesna lm79 and lm80. These manufacturing lots are picked to represent a wide parametric distribution. Lm79 lm82 lm84 independent testing laboratories, inc. The tocs complies with iesna lm79 and lm80 standards, delivering accurate and reproducible led measurements. Once the lm80 test is completed, the method recommended by iesna is applied to. Once the lm80 test is completed, the method recommended by iesna is applied to extrapolate the degradation of the luminous flux of a module or led luminaire, based on the data collected according to lm80. Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for edison opto corporation 4f, no. Star reference lm79 procedures, it is not in and of itself a lighting program with.

Lm79 is an approved method by the illuminating engineering society of north america iesna,for taking electrical and photometric measurements of ssl products. Rsz9508109000 page 5 of iesna lm8008 test report 1. Iesna,for taking electrical and photometric measurements of ssl products. At the center of the solar system, there is a smoldering ball of plasma that permits planetary orbit and helps sustain life. Base on the normal function, lisuns engineer developed new software to meet the. Lm 8008 apply to the led package, array, or module alone, not a complete system, it is testing a component level. The illuminating engineering society of north america iesna approved method for. This report is valid only with a valid digital signature. This report must not be used by the customer to claim product certification, approval, or endorsement by nvlap, nist, or any agency of the u. Lm 79 is the illuminating engineering society of north america iesna approved method for taking electrical and photometric measurements of solidstate lighting ssl products. Tm21 is important because it is referenced in the epa energy star. Rsz150414502106000 page 6 of 15 iesna lm8008 test report 1.

Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for eiko global, llc 23220 w 84th street, shawnee, ks 66227 model. It is generally established that the human eye is only sensitive to lumen depreciation of 30% or more. It was approved because it achieved the lighting energy efficiency standards required by this body. Labspheres tocs led measurement system conforms to lm79. Iesna lm 80 2008 iesna lm80kevin dowling, phd chairman, testing procedures ssl committee. Rsz14041850810 page 5 of iesna lm8008 test report 1. Therefore, l70 lifetime is defined by illuminating engineering society standard lm 80 08, entitled ies approved method for measuring lumen maintenance of led light sources. Drm is included at the request of the publisher, as it helps them protect their by restricting file sharing. Lm 80 provides no determination or estimation of expected life or lumen output beyond test data. Measuring luminous flux and color maintenance of led packages, arrays and modules published by ies on june 26, 2015 ansiies lm 80 15 provides the methods for measurement of luminous flux and color maintenance for led packages, arrays, and modules. R2dg15012005610 page 4 of 15 iesna lm8008 test report 1. This test may not be duplicated or used in part without prior written consent from bay area compliance laboratories corp.

L70 lifetime is dependent upon many variables, such as the operating temperature, drive current, and the technology and materials used to construct the products. The scope within this ansiies lm 8015 has been expanded to include tests for three types of flux maintenance along with tests for how chromaticity changes over time. R2dg15012005610 page 6 of 15 iesna lm8008 test report 1. R2dg14111005310 page 5 of 9 iesna lm8008 test report 1.

It covers total flux light output, electrical power, efficacy, chromaticity, and intensity distribution. Light laboratory is an nist nvlap accredited testing for lm79 lab code. In order to adapt to the standard, lisun developed the lpce2lms9000a high accuracy spectroradiometer and integrating sphere test system, this system not only meet the requirements of cie, en and lm79 clause 9. So lpce2 has two software, one is to test the luminous flux, color. Iesnalm80 for led lumen maintenance test lisun lisun group.

Lm 79 technical report lm 79 and lm 80 november 30, 2009. Vektrex actively participates on the lm80 committee, chairing the lm80 working group moving this standard through the acceptance process and into ieee acceptance. Light laboratory has made strides to stay current with the new testing standard lm79 set forth by the iesna illuminating engineering society of north america. Rsz140217504109000 page 5 of iesna lm8008 test report 1. Highperformance leds produce 4000 lumens and are rated to maintain 70% of light output at 50,000 hours of service. Iesna lm802008 measuring lumen maintenance of led light sources measurement and test report for. Iesna approved method for measuring lumen maintenance of led light. Ies lm7908 measurement and test report for soraa inc. The lm 80 standard calls for operating a set of led devices for a minimum of 6,000 hours under well controlled operating conditions e.

Each ts test condition is, 15, 16, 12pcs the samples tested at t. The lm7908 is an american standard created by the ies illuminating engineering society of north america in 2008. Vektrex lm80 systems are also applicable for use with laser diodes. Iesna lm79 electrical and photometric measurements of solidstate lighting products is a standard made by illuminating engineering society of north america. Ies lm84 approved method for measuring luminous flux and.

Iesna lm7908 test report at time 0 and 6,000 hours respectively. Ies approved method for measuring lumen maintenance of led light sources. Iesna tm21 technical memorandum specifies how to extrapolate the lm8008 lumen maintenance data to times beyond the lm80 test time. Bk lighting and teka illumination will provide iesna lm79 testing reports for all of our bkssl technology so that the designer can determine the suitability of our. Iesna lm80 measuring lumen maintenance of led light sources is an approved method by lighting engineering association of north america iesna for the third generation ssl products. See lighting facts labels for specific fixture performance. Find the most uptodate version of ies lm 79 at engineering360. Ies lm7908 measurement and test report for soraa,inc 6500 kaiser dr. Ies lm7908 measurement and test report for eiko global, llc 23220 w 84th st shawnee, ks 66227 test model. For a current lm80 luminaire testing and angular distribution of light measurement services price list, or if you. Led drive characteristics have been updated to include pulse width modulated current, dc constant voltage and ac regulated voltage drive. It is the illuminating engineering society of north america iesna approved standard for measuring lumen maintenance of led light sources. For a current lm 80 luminaire testing and angular distribution of light measurement services price list, or if you have any question about lm 80 please contact us.

Therefore, l70 lifetime is defined by illuminating engineering society standard lm8008, entitled ies approved method for measuring lumen maintenance of led light sources. Illuminating engineering society the lighting authority. Led lumen maintenance optical aging chamber for ieslm80 ies. Find the most uptodate version of ies lm79 at engineering360.

Lm79, lm82, lm84 testing the illuminating engineering society of north america iesna approved method for electrical and photometric measurement of solid state lighting products lm7908 is a guide developed for the measurement of solidstate led lighting products. Labspheres tocs led measurement system conforms to lm79 and. Led samples for iesna lm80 testing consist of units built from a minimum of three manufacturing lots with each manufacturing lot built from different wafer lots. This is the main test for the optical performance testing. This is the abbreviation of the illuminating engineering society of the north america. Measuring luminous flux and color maintenance of led packages, arrays and modules published by ies on june 26, 2015 ansiies lm8015 provides the methods for measurement of luminous flux and color maintenance for led packages, arrays, and modules. Vektrex offers complete lm80 test solutions that meet all iesna and energy star testing criteria. Drm is included at the request of the publisher, as it helps them protect their by restricting file.

592 901 1095 292 1198 874 522 365 644 363 720 443 1277 1095 172 1040 1203 247 1050 1014 682 1259 14 18 128 1447 727 600 159 1001 200 1337 502 1342 1405 745 493 1453 625 584 489 683 676 823 395 197 1210 1433